Purposes of AutoChem Stirred Reactors
As a type of general-pur-pose automatic reactor,it iswidely applied in substancepolymerization, decomposition,hydrothermal reaction, hydro-genation,supercritical reac-tion, pharmacy, substance dis-persion and other aspectsAlso, it can be used to store,collect and export experimen-tal data.
Structure type:Bench typefixed-head reactor; with electriclift of reactor body; horizontallyrotating 90"left and right;
Machining process:the reactor's body and head, adopt inte.grated forging and bar cuttingprocess, to ensure they have nowelding points.
Driving mode:Mechanicalstirring, magnetic sealing; driv-ing motor stepless speed regu-ation,large torque,and themaximum rotationspeed0-1200 rpm;
Sealing mode: A-type doublethread sealing,high-temperatu.re sealing gasket,snap ring type sealing structure,non-flange type sealing mode;
Heating mode:Enclosed type heating furnace, electric lift,travel300mm, horizontally rotating 90°(left-right)
Reactor cover equipped
Stainless steel pressure gauge and safety valve/explosion valye:
Thermocouple and K-type thermocouple, used to determine reaction temperature;
Liquid sampling valve and gas injection valve, connected with the depth-determining tube, used for gas intake, liquid inlet and taking liquid material under pressure;
Gas release valve,used to totally vent qas in the reactor and to release the pressure;
Built-in cooling coil, used to reduce reactor temperature;
Stirring speed control and PlD/programmed temperaturecontrol system,
Automatic cooling module, PiD control module;Digital temperature display, with super-high temperatureprotection module;
Digital pressure display and overpressure sound-light alarmmodule, with pressure sensor, revolutions control and datadisplay module;
The whole machine carries MRSC-AUTO touch screen con-trol system, to realize temperature, revolutions, torque andtime control, as well as store and collect experimental data in-cluding temperature, revolutions, pressure, torque, time andalarms.
Series MRSC-AUTO HighPressure Reactor Systems
1. ldentity recognition system, hierarchical control;2.7-inch,high-brightness, TFT LCD touch screen; show-ing abundant and comprehensive information, no deadcorner in field of vision, displayed in graphs and text,vivid, easy and simple;
3.Staged programmed temperature control; multistage ex-periment condition temperature rise mode can be set;bran-new Al (Artificial Intelligence) algorithm, to realizeno-overshoot/no-undershoot control oncomplex andlong-time logged objects.
4.Real-time online curve display for pressure, tempera-ture, rotation speed and torque;5.Automatic storage of experimental data, self-prepareddata recording function; able to display real-time data andhistorical data; also, providing data recorded in the form ofreports and alarm recording function;6.Provide with export function via USB flash disk; thusdata can be further analyzed and processed on the com-puter; so that experimental data can be stored for a longtime and be used in papers and academic research;7.Timing function: There are two modes, namely constanttemperature timing and work timing;8.Power supply configuration:110 or 200-240V/AC50-60Hz.
Select AutoChem Micro-Reactors
Model Number AutoChem100 AutoChem250 AutoChem500 AutoChem1000
Sizes,ml 100 250 500 1000
Maximum Pressure(WAWP) 10MPa(1500psi)
Maximum Temperature 350ºC
Constant temp Accuracy +1ºC
Reactor Mounting Bench Top
Rotation speed 0-1200rpm
Electrical supply
Volts,AC 100 or 220V,50Hz
Motor power(w) 70 70 150 150
Reactor Dimensions
Width,mm 290
Height.mm 550
Depth.mm 950
Materials of Construction 316LStainless steel,Alloy TA2.Alloy C-276.Nickel Alloy.Zirconium materials
Other options available,Please call for more information.
Frequently Asked Questions
1. Questions before quoting
A. Do you use gases, liquids, solids, and do you include salts, strong acids, strong bases?
B. When and where will the machine be installed?
C. What is the power supply?
D. What is the use of the high pressure reactor produced?
E. Which heating method do you prefer? Electricity or heat-conducting oil?
2. Installation and commissioning
A. The customer carries out the installation according to the manual, online instructions and SENLONG live video conference.
B. Air supply, power supply, water supply, installation tools and spare parts need to be ready before the SENLONG engineer video.
3. Warranty and Technical Support
A. 1 year from the date of bill of lading.
B. SENLONG will provide spare parts free of charge for any failure due to our responsibility during the warranty period.
C. SENLONG provides full technical support and training courses after the installation and commissioning of the machine.
C. Lifetime technical support and consultancy for the machine.
D. More than 25 engineers provide immediate after-sales service.
365 days X 7 X 24 hours phone / EMAIL assistance
4. Fault Claim Procedure
a. Request a detailed written description of the fault by fax or email, stating the relevant equipment information and a detailed description of the fault.
b. Confirmation of the failure requires relevant pictures.
c. SENLONG engineering and after-sales service team will carry out inspection and form a diagnostic report.
d. Upon receipt of the written description and pictures, further troubleshooting solutions will be provided to the customer within 24 hours.